POWER
CMP
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32S
FX iview
POWER
DEF
CMP
B3-EXT
B2-DEF
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32SD
FX iview
POWER
ALARM
CMP
B3-EXT
B2-DEF
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32SA
FX iview
POWER
FAN
CMP
B3-EXT
B2-DEF
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32SF
FX iview
POWER
DEFFAN
CMP
B3-EXT
B2-DEF
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32SB
FX iview
POWER
ALARM
DEFFAN
CMP
B3-EXT
B2-DEF
B1-AMB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-
G+
RS485, MODBUS
FX32SR
FX iview
FX32PR
4~20mA Retrans
RS485
Digital Low/High Pressure Controller
RS-485CO MM.
OPTION MODULE
1
2
3
4
TRX
TRX
SG
1
2
3
4
RXD
TXD
GND
1
2
3
4
4~20mA
4~20mA
SG
RS-232COMM.
OPTION MODULE
4~20mA Output
OPTION MODULE
Main-
Function
Input/output
Models
Power Supply
Uniform step control, operation with intelligent shift
high/low alarm output, sensor correction, sensor error detection,
transmission output, communication (RS485 MODBUS)
AC100~240V, 50/60Hz, Max. 4VA
One sensor input of 4~20 mA (embedded sensor loop power),
Four relays (three relays for step control, one relay for alarm output)
FX32PR–00 : Basic model
FX32PR–R4 : Add on RS485 communication (MODBUS)
FX32PR–A1 : Add on 4~20mA transmission output
FX32EV
RetransRS485Pt1000 4~20mA
Electronic Expansion Valve control system
1 2 43 5 6 87 9 10 11
AC100 - 240V ~
pressure
50/60Hz
FX32EV
OPTION
MODULE
tempstart
EVout
Alarm
EV
ID1
Pt1k COM
4~20mA
+V
Main-
Function
Input/output
Models
Power Supply
PID degree of superheat control through defense and safety
compensation, degree of superheat control for various refrigerant,
PMW (opening ratios control), remote operation, transmission output,
RS485 communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
SSR output 1-point (expansion valve on/off), relay output 1-point
(alarm point), temperature sensor 1-point, 4~20mA pressure sensor
input 1-point (embedded sensor loop power)
Sensor Spec
Temp. sensor (DPR-PT1K-P6D5OL, -100~100°C
Pressure sensor (-1~9 bar or 0~30 bar)
FX32EV– 00 : Basic model
FX32EV– R4 : Add on RS485 communication (MODBUS)
FX32EV– A1 : use for 4~20mA type Electronic Expansion Valve or
pressure transmission output function
FX32EV– R2 : Add on RS232 communication
FX32S series
NTC RS485
Showcase & Coldroom Controller
Compressor
Defrost
Eva Fans
Aux.output
Room Temp.
Defrost Temp.
Digital Input
(Probe3)
RTC
RS485
16A
-
-
-
-
-
-
16A
8A
-
-
-
16A
-
-
8A
-
16A
-
8A
-
-
16A
8A
8A
-
-
8A
8A
8A
8A
-
FX32SModels FX32SD FX32SA FX32SF FX32SB FX32SR
: Basic
: Option
Main-
Function
Input/output
Sensor Spec
Power Supply
Defrosting (auto/manual), defrosting stop delay, two air inlet and
outlet sensors, one sensor for defrost recovery, high(low) alarm
output, RS485 communication (MODBUS), indicator (FxiView)
connection
AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
relay output max 4-point, temperature sensor input max 3 point
DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50~105°C)
REFRIGERATION CONTROLLER
FX Series
SENSETE°CH®
CWCHEAT-EDGE®
RAINBOW
SHIMADEN
PR ELECTRONICSSEKONIC
HUBA
KAISE
OHKURACORDEX
FRIED ELECTRIC
KIMO DOTECH
V-A4
Sensing
Technology
Corporation
457-B Boni Avenue New Zaniga Mandaluyong City
Tel No.
532-0088
Fax No.
531-7387
www.heatsenze.com